Stress Echo Views

Stress Echo Views

When viewing stress echo images and loops, you have additional options for displaying loops by stage and view.

Enable Stress View button

 The Enable Stress Views button displays standard quad views for stress echo exams. When clicked, the Stress Views list at the bottom of the Study Viewer becomes active. Open the list to choose a different view.

Apply Default Stress Labels button

 The Apply Default Stress Labels button applies standard labels to the images based on the stage and view data in the DICOM. The labels are automatically applied when the study is uploaded. However, if you have overwritten the labels that were uploaded, click this button to reset them.
Info
For Stress Echo and Pharmacological Stress Echo studies, the groups and labels listed below are applied by default, but alternate lists are available. To use an alternate list, contact Studycast support.

Group

Contains Images Labeled...

Rest

Rest Ap2, Rest Ap4, Rest PLAX, Rest PSAX

Impost

Impost Ap2, Impost Ap4, Impost PLAX, Impost PSAX

Parasternal

Rest PSAX, Impost PSAX, Rest PLAX, Impost PLAX

Apical

Rest Ap2, Impost Ap2, Rest Ap 4, Impost Ap4

Low

Low Ap2, Low Ap4, Low PLAX, Low PSAX

Inter

Inter Ap2, Inter Ap4, Inter PLAX, Inter PSAX

Peak

Peak A2C, Peak A4C, Peak PLAX, Peak PSAX

Recovery

Recovery A2C, Recovery A4C, Recovery PLAX, Recovery PSAX

Ap2 Pharm

Rest Ap2, Low Ap2, Inter Ap2, Impost Ap2

Ap4 Pharm

Rest Ap4, Low Ap4, Inter Ap4, Impost Ap4

PLAX Pharm

Rest PLAX, Low PLAX, Inter PLAX, Impost PLAX

PSAX Pharm

Rest PSAX, Low PSAX, Inter PSAX, Impost PSAX

 

Creating Custom Views

In addition to the standard stress views, you can create custom groups that include images or loops you choose.

 

To create and view a custom group:

1.Select an item in the list of thumbnails on the left side of the Study Viewer.

2.In the top left of the image pane, click No label.  In the menu that opens, select a label for the current item. To create custom groups, select one of the numbered custom labels.

3.Repeat steps 1 and 2 for each item you want to label.

4.When you are finished labeling items,  click the Enable Stress View icon to the left of the viewing pane. The Stress Views list below the viewing pane is now active.

5.Open the Stress Views list to select a different view. The menu includes groups listed in the table below, as appropriate, and two custom groups, the images you labeled Custom 1-4 and the images you labeled Custom 5-8.

 
    • Related Articles

    • Stress Echo

      Calculated Fields In the Stress Echo worksheet, the following fields are calculated automatically. These calculated values automatically update when any of the source values are changed. Field Source Values Calculation Logic Max APHR Patient Age 220 ...
    • Echo

      Calculated Fields In the Echo worksheet, the following fields are calculated automatically. These calculated values automatically update when any of the source values are changed. For values that can be calculated using multiple methods, the Priority ...
    • Split Valve Structure/Function Statement Option (Echo)

      Studycast offers an option for your Echo worksheet and reports to either combine or split Valve Structure statements. You can use this option to enhance or condense the valve statements as desired for your Echo worksheets and reports. To ...
    • Study Type Codes

      Study Type Codes See this article in Studycast Help STUDYTYPE PROTOCOL ALIAS AAA aaa Abdomen Abdomen abd Abdomen Gallbladder gall Abdomen Liver liv Abdomen Renal ren Abdomen Retroperitoneal ret Abdomen RUQ ruq Abdomen (Vet) abdvet Abdomen and Pelvis ...
    • Studycast Study Types